A methodology for classifying root causes of outbreaks of Legionnaires' disease: Deficiencies in environmental control and water management
Clopper BR , Kunz JM , Salandy SW , Smith JC , Hubbard BC , Sarisky JP . Microorganisms 2021 9 (1) We piloted a methodology for collecting and interpreting root cause-or environmental deficiency (ED)-information from Legionnaires' disease (LD) outbreak investigation reports. The methodology included a classification framework to assess common failures observed in the implementation of water management programs (WMPs). We reviewed reports from fourteen CDC-led investigations between 1 January 2015 and 21 June 2019 to identify EDs associated with outbreaks of LD. We developed an abstraction guide to standardize data collection from outbreak reports and define relevant parameters. We categorized each ED according to three criteria: ED type, WMP-deficiency type, and source of deficiency. We calculated the prevalence of EDs among facilities and explored differences between facilities with and without WMPs. A majority of EDs identified (81%) were classified as process failures. Facilities with WMPs (n = 8) had lower prevalence of EDs attributed to plumbed devices (9.1%) and infrastructure design (0%) than facilities without WMPs (n = 6; 33.3% and 24.2%, respectively). About three quarters (72%) of LD cases and 81% of the fatalities in our sample originated at facilities without a WMP. This report highlights the importance of WMPs in preventing and mitigating outbreaks of LD. Building water system process management is a primary obstacle toward limiting the root causes of LD outbreaks. Greater emphasis on the documentation, verification, validation, and continuous program review steps will be important in maximizing the effectiveness of WMPs. |
Lessons from an outbreak of Legionnaires' disease on a hematology-oncology unit
Francois Watkins LK , Toews KE , Harris AM , Davidson S , Ayers-Millsap S , Lucas CE , Hubbard BC , Kozak-Muiznieks NA , Khan E , Kutty PK . Infect Control Hosp Epidemiol 2017 38 (3) 306-313 OBJECTIVES To define the scope of an outbreak of Legionnaires' disease (LD), to identify the source, and to stop transmission. DESIGN AND SETTING Epidemiologic investigation of an LD outbreak among patients and a visitor exposed to a newly constructed hematology-oncology unit. METHODS An LD case was defined as radiographically confirmed pneumonia in a person with positive urinary antigen testing and/or respiratory culture for Legionella and exposure to the hematology-oncology unit after February 20, 2014. Cases were classified as definitely or probably healthcare-associated based on whether they were exposed to the unit for all or part of the incubation period (2-10 days). We conducted an environmental assessment and collected water samples for culture. Clinical and environmental isolates were compared by monoclonal antibody (MAb) and sequence-based typing. RESULTS Over a 12-week period, 10 cases were identified, including 6 definite and 4 probable cases. Environmental sampling revealed Legionella pneumophila serogroup 1 (Lp1) in the potable water at 9 of 10 unit sites (90%), including all patient rooms tested. The 3 clinical isolates were identical to environmental isolates from the unit (MAb2-positive, sequence type ST36). No cases occurred with exposure after the implementation of water restrictions followed by point-of-use filters. CONCLUSIONS Contamination of the unit's potable water system with Lp1 strain ST36 was the likely source of this outbreak. Healthcare providers should routinely test patients who develop pneumonia at least 2 days after hospital admission for LD. A single case of LD that is definitely healthcare associated should prompt a full investigation. Infect Control Hosp Epidemiol 2017;38:306-313. |
- Page last reviewed:Feb 1, 2024
- Page last updated:May 06, 2024
- Content source:
- Powered by CDC PHGKB Infrastructure